Hardware › Scale

Datalogic Magellan 9800i scanner-scale

Set up a Datalogic Magellan 9800i counter scanner-scale on one cable: it scans barcodes and weighs loose items for the itsPOS till.

Print the set-up guide for your cables:

Print at 100% ("Actual size") on white paper. Which one, and how to tell your cables apart: Set up a Datalogic Magellan 9800i scanner-scale.

Tested on a real Magellan 9800i with the one-cable guide (RS-232 to COM1): the weights on the till matched the scale's display. The USB-cable guide is new and hasn't been tested on a real device yet: tell us if something doesn't match what you see.

Which set-up do you need?

The Magellan can work with the till in two ways. Choose before you start, because the setup barcodes are different.

What differs One cable (this guide) Two cables, Dialog06 (its own guide) Two serial cables, Dialog06 (its own guide)
Cables One USB cable (or one RS-232 cable) carries barcodes and weight USB for the barcodes, plus a serial cable from the scale port HOST port to the till's COM1 for the barcodes, SCALE HOST port to COM2 for the scale
Who works out the price The till The scale The scale
Selling by weight to the public Once an approved verifier has checked the scale with this itsPOS till in your shop and an Owner or Admin switches on trade use The planned set-up for selling by weight, once the scale and till are approved in your shop The same as Dialog06 over USB: for selling by weight once the scale and till are approved in your shop

In the UK a scale used to sell goods by weight must be approved for trade, and when it is connected to a till the scale and the till must be approved together. With one cable the till works out the price from the scale's weight, so the verifier must check this scale with this itsPOS till: an approval of the Magellan with another till system doesn't count. Until trade use is switched on, weighing works for training and checks only. Your business is responsible for the set-up and its verification; see Selling by weight legally. If a verifier won't pass the one-cable set-up, Magellan 9800i with Dialog06 (or two serial cables) lets the scale work out the price instead.

What you need

One cable: the Magellan's USB cable goes into the till; barcodes and the weight travel on the same cable

1. Choose the scanner-scale in the back office

Only an Owner or Admin can change the scale in a till profile.

  1. In the back office, open your till profile (see below).
  2. Under Scanner, set Scanner type to Scanner-scale on a serial port (Datalogic Magellan).
  3. Under Scale, set Scale to Datalogic Magellan 9800i.
  4. Press Save changes. Tills using the profile show "Scale needs re-checking"; that's expected. Trade use stays off until an Owner or Admin switches it on (step 6).

Where to find the till profile in the back office

Settings that are the same for every till of a kind live in a till profile in the back office, not on the till. Sign in at app.itspos.io, open Settings › Till profiles and open the profile your tills use (most shops have one, called Standard). Change the value and press Save changes: every till using that profile gets it within a minute, between sales. Owners and Admins change till profiles; Shop managers change them for their own shops. The till shows the values it got at the bottom of Settings › Hardware, under Till profile.

A till profile in the back office: each device choice shows its model, the "Built from the maker's documentation" badge and a link to its setup guide

2. Scan the setup barcodes

With the RS-232 cable (HOST PORT to COM1): the printed guide

Use the one-cable guide (PDF, 9 pages), not the barcodes on this page.

  1. Print it at 100% ("Actual size", not "Fit to page") on white paper. Don't scan from a phone or a screen.
  2. Unplug the cable at the till end (COM1) and leave the Magellan switched on. Datalogic warns that changing the cable type while it's plugged in can damage the scanner or the till's port.
  3. Scan its barcodes 1 to 16 in order, one at a time: cover the other barcodes, hold the page 10 to 15 cm from the upright window, wait for the short run of beeps and the restart (2 to 3 seconds), then tick the box. Each barcode is complete on its own: there are no Enter/Exit barcodes, so don't mix them with an older Magellan guide.
  4. Only if your shop needs them, scan its extra pages: security tags, a handheld scanner plugged into the Magellan, or a reader on an arm above it.

What they do: barcode 1 puts the Magellan back to its factory settings and barcode 2 sets the cable (RS-232 single cable); 3 to 12 add the code that tells the till what kind of barcode it is, stop a second weight until the scale has been back at zero, stop staff forcing a weight while an item hangs over the edge, and turn on QR codes (itsPass), Data Matrix and GS1 DataBar (fresh food); 13 to 15 read codes on phone screens; 16 tells the Magellan it has no reader on an arm. Then go on with step 3.

With the USB cable (HOST PORT to a USB socket): the printed USB guide

Use the USB-cable guide (PDF, 9 pages). It's new and hasn't been tested on a real Magellan yet.

  1. Print it at 100% ("Actual size") on white paper.
  2. Unplug the USB cable at the till end and leave the Magellan switched on.
  3. Scan its barcodes 1 to 16 in order, one at a time, as above. They're the same as the one-cable guide's, except barcode 2, which sets the cable to USB COM: the till then sees the Magellan as a COM port.
  4. Only if your shop needs them, scan its extra pages.

Then go on with step 3. On Windows, the guide's step 4 also covers Datalogic's USB-COM driver.

3. Plug it in

  1. Plug the Magellan's cable into the till: the RS-232 cable from the blue HOST PORT into COM1 (or into the USB-to-serial adapter, then the adapter into the till), or the USB cable into a USB socket. A second cable from the green SCALE HOST port to COM2 can stay plugged in: this set-up doesn't use it.
  2. Mac: nothing to install.
  3. Windows: Windows finds it by itself. If the till can't find it, or it moves to a different "COM" number each time you change USB socket, install Datalogic's free USB-COM driver and turn on its fixed COM number option.

4. Set it up on the till

Only an Owner or Admin can turn the scanner-scale on; shop managers and supervisors can run the tests.

  1. On the till, open Settings › Hardware and press Change on the Scale row. The panel is called Scanner-scale.
  2. With the RS-232 cable, choose its port (COM1; with an adapter on a Mac, the one starting /dev/cu.) and Serial cable (RS-232). With the USB cable, leave the port on Find automatically (Datalogic) and the cable on USB cable. The cable is this till's own wiring, so you choose it here even when the till profile comes from the back office (till 0.5.39 and later; on 0.5.38 and earlier update the till first).
  3. Press Turn on (or Save if it's already on). The toast says Scanner-scale saved. and the row says Connected on ….

Where to find the Hardware screen on the till

On the till, tap Settings, then Hardware. Each device has a row with its status, the model and its badge, a Setup guide button and a large test button.

Setup guide opens this page: Open in the browser shows it on the till's computer (not in kiosk mode), and Print the link prints the address with a QR code to scan with a phone.

Every test asks you whether it worked (Yes or No). The answer is saved with the till, and your manager sees it in the back office under Settings › Tills and devices, in the till's Hardware tests.

The Hardware screen on the itsPOS till: a row for each device with its status, Setup guide, Change and its test button

The Scale row says Not for trade use until an Owner or Admin switches on trade use in the back office (till 0.5.37 and earlier: "until the itsPOS support team approves it"), and the panel says weighing works for training and checks. That's expected until trade use is switched on (step 6).

5. Test it

Wait 15 minutes after switching the Magellan on before you test the weight.

  1. Weight: on the Scale row, press Read weight. Put something you know the weight of on the platter (for example a 1 kg bag of sugar). The till shows the live weight and asks "Put something you know the weight of on the scale. Is the weight right?" Press Yes.
  2. Zero: press Zero. Take everything off; the till asks "Take everything off the scale. Does it read 0.000 kg?" Press Yes.
  3. Barcodes: on the Scanner row, press Test scan and scan a product, then the test QR code on page 6 of the one-cable guide (the till shows ITSPOS QR TEST 123), then an itsPass code on a phone (brightness full, 10 to 15 cm from the upright window, tilted slightly), then a fresh food barcode if you have one.
  4. Security tags (only if you scanned a security tag barcode): on the Scanner row, press Security tags. Scan the barcode of an item with a security tag over the Magellan, walk it through the shop's security gate, and answer "Did the gate stay quiet?"

Every result is saved with the till, so your manager can see it in the back office under Settings › Tills and devices. On the Scanner row, Scanner health shows what the Magellan reports about itself (the itsPOS support team may ask you to open it).

6. Switch on trade use (to sell by weight) {#trade-use}

Only after an approved verifier or Trading Standards has checked this Magellan with this itsPOS till in your shop. An approval of the Magellan with another till system doesn't count, because here the till works out the price.

  1. In the back office, an Owner or Admin opens Settings › Compliance › Weighed goods and presses Switch on trade use on the till's row.
  2. Optionally type the scale's serial number and who checked it and when, then tick the declaration. Under it the dialog says The verifier must check this scale with this itsPOS till. An approval for another till system doesn't count.
  3. Press Switch on trade use. Within a minute the till's Scale row says Trade use on and The till works out the price from the scale's weight (till 0.5.41 and later).

The verifier reads the till's weighing software on the till: Settings › Hardware, Scale row, "Weighing software 1.0.0 · checksum 3afbc0df" (till 0.5.43 and later; Change shows the full checksum). An update that changes it switches trade use off with Scale needs re-checking, like a change of the scale.

Any change of the scale, its cable or its port switches trade use off again and shows Scale needs re-checking. Full steps: Selling by weight legally › Switch on trade use.

What this changes

Common problems

What happens What to do
Scanner-scale not found. Check the USB cable. Check the cable at both ends (the blue HOST PORT and the till's USB socket) and that the Magellan is on. Make sure you scanned barcode 2 of the USB-cable guide (USB COM). On Windows, check Device Manager › Ports (COM & LPT); if it isn't there, or its COM number keeps changing, install Datalogic's USB-COM driver and turn on its fixed COM number option.
Scanner-scale not responding Unplug the cable for 10 seconds and plug it back in. The till reconnects by itself within a few seconds.
With the RS-232 cable, nothing arrives at all The Magellan waits for the till's "ready" signal before it sends anything, which the till sends when it opens the port. Check the cable is in COM1 (or the adapter) and in the blue HOST PORT, and that you chose Serial cable (RS-232) and its port in Change. Still nothing: unplug the cable from the till and start again from barcode 1 of the printed guide.
A setting barcode gives no beeps Cover the other barcodes and move the page slowly nearer and further from the upright window. If the Magellan's lights are off, wave a hand in front of it. Check you printed at 100% size.
Six very quick chirps and no restart The Magellan refused the barcode: cover the others and scan it again. Still the same: take everything off the platter, pull its power plug for 30 seconds and scan it again. Barcodes 14 and 15 are for newer Magellans: if one of them chirps, carry on.
The green light flashes slowly, one second on and one second off The Magellan is waiting for setting barcodes, usually after an Enter/Exit barcode from an older guide. Pull its power plug for 30 seconds, plug it back in and scan the barcode again.
Product barcodes scan, but QR codes, itsPass codes or fresh food barcodes don't QR, Data Matrix and GS1 DataBar are off from the factory. Scan barcodes 7 to 12 of the printed guide again (still the same: start again from barcode 1).
No square code reads at all, not even the test QR code on paper If products still scan after barcodes 7 to 12, the Magellan's 2D camera may need a repair: QR codes, itsPass codes, Data Matrix and reading from phone screens all depend on it. Call us.
The test QR code scans from paper, but not from a phone Printed guide: scan barcodes 13 to 15 again. Turn the phone's brightness up, hold it 10 to 15 cm from the upright window and tilt it slightly; switch off dark mode so the code is dark on white.
Press zero on the scanner-scale Take everything off the platter and press the zero button on the Magellan. If it keeps coming back, the scale needs a service: call us.
Make sure the item is fully on the platter Something hangs over the edge of the platter (the Magellan's edge guard sees it). Move it onto the platter.
Too heavy for the scale (max 15 kg) Weigh it in smaller parts.
Scale is set to pounds The scale must weigh in kilograms. It needs the approved verifier to change it: call us.
The next item won't weigh after the last one The scale waits to go back to zero between items. Take everything off, then weigh the next item.
The weight jumps about Keep the platter clear and still, away from fans or draughts. Wait 15 minutes after switching on.
A yellow Scale needs re-checking note Someone changed the scale settings or its connection, so trade use is off. Once the new set-up has been checked with this till, an Owner or Admin switches on trade use again in Settings › Compliance › Weighed goods, or presses Keep it off to clear the note.

For installers

Still stuck?

The itsPOS support team is here 08:00 to 20:00 every day except Christmas Day.

Tell us your shop's name and what you were trying to do. A screenshot of the screen helps.

For a device, tell us its model and the till's name, and if you can, send a photo of the device's cables and of the till's Settings › Hardware screen.