Datalogic Magellan 9800i with Dialog06 (the scale works out the price)
Set up a Datalogic Magellan 9800i on two cables: the scanner types barcodes into the till over USB, and the scale works out the price over a second, serial cable. This is the planned set-up for selling by weight.
Is your Magellan on serial cables? Print its set-up guide instead:
This page is for a Magellan whose scanner types into the till over a USB cable while a second cable goes to the scale. Otherwise download the printed guide for your cables:
- Download the two-cable guide (PDF, 11 pages)The blue HOST PORT to the till's COM1 and the green SCALE HOST port to COM2, where the scale works out the price, as on this page.
- Download the one-cable guide (PDF, 9 pages)One cable from the HOST PORT to COM1 for the barcodes and the weight.
- Download the USB-cable guide (PDF, 9 pages)One USB cable from the HOST PORT for the barcodes and the weight, no scale cable. New: not tested on a real device yet.
How to tell your cables apart: Set up a Datalogic Magellan 9800i scanner-scale.
Built from the maker's documentation. We wrote this guide and the till's driver from the maker's own manuals and programming guides. We haven't checked this model on a real device yet, so tell us if something here doesn't match what you see.
The scale side of this set-up (Dialog06 on the SCALE HOST port) was tested on a real Magellan 9800i with the two serial cables guide: the weights on the till matched the scale's display. The USB keyboard scanner on this page hasn't been tested yet.
How it works
The till sends the scale the item's price per kg. The Magellan weighs, works out the price itself and sends the weight, the price per kg and the price back, and the till puts them on the sale and the receipt unchanged. Datalogic calls this scale mode Dialog06.
In the UK a scale used to sell goods by weight must be approved for trade, and when it is connected to a till the scale and the till must be approved together. Every till shows Not for trade use until an approved verifier or Trading Standards has checked the scale and the till together in your shop and an Owner or Admin has switched on trade use in the back office, ticking a declaration that the set-up is verified (Selling by weight legally › Switch on trade use). We have asked Datalogic to confirm that its UK approval covers this set-up with a PC till: ask your verifier, and us, before you switch on trade use. See Selling by weight legally.
The Magellan 9300i and 9400i also have a Dialog06 scale mode. They aren't in the till profile's list yet: ask us before you buy one.
If your Magellan is wired with two serial cables (its HOST port to the till's COM1, its SCALE HOST port to COM2), use the two serial cables guide instead: the barcodes then come on COM1, not over USB. If you only want to weigh for training and checks on one cable, use the one-cable guide.
What you need
- The Magellan 9800i and its USB cable for the scanner.
- A serial cable for the Magellan's scale port and a USB-to-serial adapter (FTDI or Prolific) for the till. Ask us for the right cable.
- The customer display switched on, so customers can see the weight and the price (customer display guide).
- This page printed on paper, for the setup barcodes.
- 15 minutes after switching on before you weigh: the scale needs to warm up.
- Datalogic's own documentation: the Magellan 9800i data sheet and the Product Reference Guide (search Datalogic's site); Dialog06 is the scale interface code
040411in its scale chapter.
1. Set it up in the back office
Only an Owner or Admin can change the scale in a till profile.
- In the back office, open your till profile (see below).
- Under Scanner, set Scanner type to USB scanner (types like a keyboard): in this set-up the Magellan's scanner types like a handheld scanner.
- Under Scale, set Scale to Datalogic Magellan 9800i (Dialog06: the scale works out the price).
- Press Save changes. Tills using the profile show "Scale needs re-checking", and trade use is off, until an Owner or Admin switches on trade use again once the scale has been checked with the till; that's expected.
Where to find the till profile in the back office
Settings that are the same for every till of a kind live in a till profile in the back office, not on the till. Sign in at app.itspos.io, open Settings › Till profiles and open the profile your tills use (most shops have one, called Standard). Change the value and press Save changes: every till using that profile gets it within a minute, between sales. Owners and Admins change till profiles; Shop managers change them for their own shops. The till shows the values it got at the bottom of Settings › Hardware, under Till profile.

2. Set the till's keyboard to UK
The scanner types each barcode, so the till's keyboard must be UK:
- Windows: in Windows Settings, Time & language, Language & region, keep only the United Kingdom keyboard.
- Mac: in System Settings, Keyboard, Text Input, use British – PC (not British).
3. Scan the setup barcodes
Each group starts and ends with Enter/Exit Programming Mode: scan it, scan the codes in the group from top to bottom (each gives three beeps), then scan Enter/Exit Programming Mode again to save.
Group 1: the scanner cable. Unplug the cables from the till first. Choosing the cable type puts every other setting back to the factory settings, so always do this group first.
Enter/Exit Programming Mode
From Datalogic Magellan 9800i Product Reference Guide (820048614, 2016).
Interface Type = USB Keyboard
From Datalogic Magellan 9800i Product Reference Guide (820048614, 2016).
Then Enter/Exit Programming Mode again. The Magellan restarts.
Group 2: the scanner and scale settings. Enter/Exit, then these from top to bottom, then Enter/Exit again:
Enter/Exit Programming Mode
From Datalogic Magellan 9800i Product Reference Guide (820048614, 2016).
USB Keyboard Country Mode = Britain
From Datalogic Magellan 9800i Product Reference Guide (820048614, 2016).
Global AIM ID = Enable Label ID Control = Disable Scale Enforced Zero Return = no zero between weights ScaleSentry Override Button = Disable QR Code = Enable GS1 QR Code = Enable Data Matrix = Enable GS1 Data Matrix = Enable GS1 DataBar Omnidirectional = Enable GS1 DataBar Expanded = Enable
From Datalogic Magellan 9800i Product Reference Guide (820048614, 2016).
Scale Interface Type = Dialog06 Scale Baud Rate = 9600 Scale Interface Options = clear the unit price after every price-weight request
From Datalogic Magellan 9800i Product Reference Guide (820048614, 2016).
What they do: set the keyboard to UK; add a short code before each barcode that tells the till what kind of barcode it is; stop the scale giving a second weight until it has gone back to zero; stop staff forcing a weight while an item hangs over the edge; turn on QR codes, Data Matrix and GS1 DataBar (off from the factory); and set the scale port to Dialog06 at 9600 baud, clearing the price after each weighing so an old price is never used again.
If your shop has security tags or a handheld plugged into the Magellan, scan the line you need from extra page 1 of the USB-cable guide (PDF) after group 2. Each of its barcodes works on its own: don't scan Enter/Exit Programming Mode before or after it.
4. Plug it in and check the scanner
- Plug the scanner's USB cable into the till, and the scale port's serial cable into the USB-to-serial adapter, then the adapter into the till.
- On the till, open Settings › Hardware. On the Scanner row press Test scan and scan a product, then an itsPass code or a QR code on a phone. The till shows "The scanner works."
Set it up on the till
Only an Owner or Admin can choose the scale's port. Shop managers and supervisors can run the tests below.
- Plug the USB-to-serial adapter into the till.
- On the till, open Settings › Hardware and press Change on the Scale row. The panel says The scale works out the price and Only an Owner or Admin changes the scale.
- Choose the adapter in Choose the scale's port. The till can't find this scale by itself. If you're not sure which port it is, unplug the adapter, look at the list, plug it back in and pick the one that appeared.
- Windows: the adapter shows as a COM port, for example COM3. If no new port appears, install the driver from the adapter's maker.
- Mac: pick the port that starts /dev/cu. (for example /dev/cu.usbserial-A10K), not the one that starts /dev/tty.
- Press Turn on. The toast says Scale saved. and the Scale row says Connected on … and The scale works out the price.
- When the scale first starts, it asks the till for a check. Once it accepts it, Change shows Scale check: The scale accepted this till.
Where to find the Hardware screen on the till
On the till, tap Settings, then Hardware. Each device has a row with its status, the model and its badge, a Setup guide button and a large test button.
- Owners, Admins, Shop managers and Supervisors open Hardware and run the tests.
- Owners, Admins and Shop managers also see Change on a row, to set how the device is connected to this till. Only Owners and Admins change the scale.
- Cashiers see Hardware greyed out with "Not allowed for your role". A supervisor or manager signs in to run a test.
Setup guide opens this page: Open in the browser shows it on the till's computer (not in kiosk mode), and Print the link prints the address with a QR code to scan with a phone.
Every test asks you whether it worked (Yes or No). The answer is saved with the till, and your manager sees it in the back office under Settings › Tills and devices, in the till's Hardware tests.

Until trade use is switched on for this till, the Scale row says Not for trade use until an Owner or Admin switches on trade use in the back office (till 0.5.37 and earlier: "until the itsPOS support team approves it"), and weighed items can't be sold from the scale. Once an approved verifier or Trading Standards has checked the scale and the till together in your shop, an Owner or Admin switches it on in Settings › Compliance › Weighed goods, ticking a declaration that the set-up is verified: Selling by weight legally › Switch on trade use.
The verifier reads the till's weighing software on the till: Settings › Hardware, Scale row, "Weighing software 1.0.0 · checksum 3afbc0df" (till 0.5.43 and later; Change shows the full checksum). An update that changes it switches trade use off with Scale needs re-checking, like a change of the scale.
Test it
- On the Scale row, press Read weight. The till sends the scale a test price of £1.00 per kg.
- Put something you know the weight of on the scale, for example a 1 kg bag of sugar, and press Weigh.
- The till shows the scale's answer, for example 1.000 kg · £1.00. If the weight is right and the price matches it, press Yes; otherwise No.
The result is saved with the till, and your manager sees it in the back office under Settings › Tills and devices. There is no Zero button for this scale: zero it with the scale's own zero key.
When you sell, the receipt and the customer display show the weight, the price per kg and the price exactly as the scale worked them out; staff can't change them on the till.
What this changes
- Sell: tapping or scanning a product sold by weight opens the weigh sheet with The scale works out the price; the till sends the product's price per kg (and its tare) to the scale.
- Receipts: a weighed sale needs a working receipt printer, so keep paper in it.
- Back office: the test results show in Settings › Tills and devices; Settings › Compliance › Weighed goods lists each till's scale and its trade use, where an Owner or Admin switches it on or off.
Common problems
| What the till says | What to do |
|---|---|
| Choose the scale's port. | In Change, pick the adapter's port, then Turn on. |
| Scale not responding or The scale isn't answering. Check it is on and the cable. | Check the scale is on and the serial cable is plugged in at both ends. Unplug the adapter for 10 seconds and plug it back in. |
| Can't open the scale's port (…) | Another program is using the adapter, or it was unplugged. Close the other program, plug the adapter back in, then Turn on again. |
| The scale didn't understand the till. Check the cable. | The cable or the adapter is loose or the wrong kind. Use the cable that came with the scale. |
| The scale didn't accept the till's message. Check the scale's settings. | The scale isn't set to Dialog 06 at 9600 baud. Don't change its settings yourself: call us. |
| The scale reports an error. Switch it off and on. | Switch the scale off and on. If it keeps happening, call us. |
| The scale didn't accept this till's check. Ask the itsPOS support team to set the scale check for this till. | Call us: the itsPOS support team sets the check for each till when the scale is approved in your shop. |
| Take the item off the scale and put it on again | Lift the item off, wait for zero, then put it back. |
| Below the scale's smallest weight | The item is too light for this scale to price by weight. |
| Press zero on the scale | Take everything off and press the scale's zero key. |
| Too heavy for the scale | Weigh it in smaller parts. |
| Make sure the item is fully on the scale | Nothing may hang over the edge or touch the scale. Move the item onto the scale. |
| The scale used a different price per kg. Check the scale. | The scale used its own price for this item, so the till refused the weighing: a customer is never charged a price the till didn't send. Weigh again; if it repeats, call us. |
| The scale is set to pounds | The scale must weigh in kilograms, and only its verifier can change that: call us. |
| This scale is not for trade use. An Owner or Admin switches on trade use in the back office once the scale and till have been checked. (till 0.5.37 and earlier: "This scale is not approved for trade use yet.") | Expected until trade use is switched on for this till: Selling by weight legally › Switch on trade use. |
For installers
- Scanner: Interface Type USB Keyboard (
000135), country Britain (030202), Global AIM ID on (03A901), Label ID off (020500), 2D and DataBar on as in the one-cable guide; the till reads it as a keyboard scanner (scanner.typeusb). - Scale port: Scale Interface Type Dialog06 (
040411), Scale Baud Rate 9600 (041304), Scale Interface Options "clear the unit price after every price-weight request" (041708). Checkout-Dialog 06 at 9600 baud, 7 data bits, odd parity, 1 stop bit, no handshake lines; the port is chosen by hand on the till. - How the 9800i answers the scale check (records 10 and 11) for a PC till is still to be confirmed by Datalogic; until then the till answers with the pairs the itsPOS support team sets, or its own.
Still stuck?
The itsPOS support team is here 08:00 to 20:00 every day except Christmas Day.
- Call or WhatsApp: +44 7488 880320
- Email: support@itspos.io
- In the back office: Help › Contact support, or go to app.itspos.io/help/contact after you sign in
- On our website: itspos.io/contact
Tell us your shop's name and what you were trying to do. A screenshot of the screen helps.
For a device, tell us its model and the till's name, and if you can, send a photo of the device's cables and of the till's Settings › Hardware screen.