Datalogic Magellan 9800i on two serial cables (HOST to COM1, SCALE to COM2)
Set up a Datalogic Magellan 9800i wired to the till with two RS-232 cables: the Magellan's HOST port goes to the till's COM1 and carries the barcodes, and its SCALE HOST port goes to the till's COM2, where the scale works out the price. Many shops moving from another till already have this wiring.
Print the set-up guide for your cables:
- Download the two-cable guide (PDF, 11 pages)The blue HOST PORT to the till's COM1 for the barcodes and the green SCALE HOST port to COM2, where the scale works out the price. It has barcodes 1 to 25, the till steps and the test.
- Download the one-cable guide (PDF, 9 pages)Only one cable, from the HOST PORT to COM1, carrying the barcodes and the weight (its online guide).
- Download the USB-cable guide (PDF, 9 pages)One USB cable from the HOST PORT to a USB socket on the till. New: not tested on a real device yet.
Print at 100% ("Actual size") on white paper. Which one, and how to tell your cables apart: Set up a Datalogic Magellan 9800i scanner-scale.
Tested on a real Magellan 9800i with the printed two-cable guide: the weights on the till matched the scale's display.
How it works
- Barcodes: the Magellan sends each barcode down the HOST cable. The till reads them from COM1, so they work everywhere a scan works: products, itsPass codes, GS1 DataBar on fresh food, and batch and use-by codes.
- Weighing: the till sends the scale the item's price per kg on COM2. The Magellan weighs, works out the price itself and sends the weight, the price per kg and the price back, and the till puts them on the sale and the receipt unchanged. Datalogic calls this scale mode Dialog06; it is the same scale set-up as the Magellan 9800i with Dialog06 guide, where the barcodes go over USB instead.
In the UK a scale used to sell goods by weight must be approved for trade, and when it is connected to a till the scale and the till must be approved together. Every till shows Not for trade use until an approved verifier or Trading Standards has checked the scale and the till together in your shop and an Owner or Admin has switched on trade use in the back office, ticking a declaration that the set-up is verified (Selling by weight legally › Switch on trade use). We have asked Datalogic to confirm that its UK approval covers this set-up with a PC till: ask your verifier, and us, before you switch on trade use.
This is not the one-cable set-up. Don't use the Magellan's RS-232 Single Cable mode here: it sends the weight down the HOST cable and leaves the SCALE HOST port unused, and the till never sells a weighed item from it (one-cable guide).
What you need
- The Magellan 9800i with two RS-232 cables: one from its HOST port, one from its SCALE HOST port. Shops moving from another till usually have both already; ask us if you need cables.
- A till with two serial ports (COM1 and COM2), or a USB-to-serial adapter (FTDI or Prolific) for each cable the till has no port for. Each adapter shows as its own COM port.
- The customer display switched on, so customers can see the weight and the price (customer display guide).
- The two-cable guide (PDF) printed on paper at 100% size, for the setup barcodes.
- 15 minutes after switching on before you weigh: the scale needs to warm up.
- Datalogic's own documentation: the Magellan 9800i data sheet and the Product Reference Guide (search Datalogic's site).
1. Set it up in the back office
Only an Owner or Admin can change the scale in a till profile.
- In the back office, open your till profile (see below).
- Under Scanner, set Scanner type to Scanner on its own serial port (RS-232).
- Under Scale, set Scale to Datalogic Magellan 9800i (Dialog06: the scale works out the price).
- Press Save changes. Tills using the profile show "Scale needs re-checking", and trade use is off, until an Owner or Admin switches on trade use again once the scale has been checked with the till; that's expected.
Where to find the till profile in the back office
Settings that are the same for every till of a kind live in a till profile in the back office, not on the till. Sign in at app.itspos.io, open Settings › Till profiles and open the profile your tills use (most shops have one, called Standard). Change the value and press Save changes: every till using that profile gets it within a minute, between sales. Owners and Admins change till profiles; Shop managers change them for their own shops. The till shows the values it got at the bottom of Settings › Hardware, under Till profile.

2. Scan the setup barcodes
Use the printed two-cable guide (PDF, 11 pages). If the Magellan was set up on one cable before, these barcodes replace that set-up.
- Print it at 100% ("Actual size", not "Fit to page") on white paper. Don't scan from a phone or a screen.
- Unplug both cables at the till end: COM1 and COM2. Leave the Magellan switched on. Datalogic warns that changing the cable type while it's plugged in can damage the scanner or the till's port.
- Scan its barcodes 1 to 25 in order, one at a time: cover the other barcodes, hold the page 10 to 15 cm from the upright window, wait for the short run of beeps and the restart (2 to 3 seconds), then tick the box. Each barcode is complete on its own: there are no Enter/Exit barcodes, so don't mix them with an older Magellan guide.
- Only if your shop needs them, scan its extra pages: security tags, a handheld scanner plugged into the Magellan, or a reader on an arm above it.
What they do:
- 1 and 2: put the Magellan back to its factory settings and set the HOST PORT to RS-232 Standard (barcodes only). Don't use the one-cable guide's RS-232 Single Cable barcode here.
- 3 to 12: add a short code before each barcode that tells the till what kind of barcode it is; stop the scale giving a second weight until it has gone back to zero; stop staff forcing a weight while an item hangs over the edge; turn on QR codes (itsPass), Data Matrix and GS1 DataBar (fresh food), which are off from the factory.
- 13 to 16: read codes on phone screens, and tell the Magellan it has no reader on an arm.
- 17 to 19: set the SCALE HOST port to Dialog06 at 9600 baud, clearing the price after each weighing so an old price is never used again.
- 20 to 25: the HOST PORT's factory speed, scanned to be sure an earlier set-up didn't change it: 9600 baud, 8 data bits, 1 stop bit, no parity, no hardware handshake, and a carriage return after each barcode.
3. Plug it in
- Plug the cable from the Magellan's HOST port into the till's COM1.
- Plug the cable from the Magellan's SCALE HOST port into the till's COM2.
- With USB-to-serial adapters, plug each cable into its adapter and the adapters into the till. On Windows, Device Manager lists each one's COM number under Ports (COM & LPT).
- If an earlier till program is still installed on the computer, close it and stop it starting with Windows: a port can only be used by one program at a time.
4. Choose the ports on the till
Only an Owner or Admin can choose the scanner's and the scale's ports. Shop managers and supervisors can run the tests below.
The scanner (COM1):
- On the till, open Settings › Hardware and press Change on the Scanner row. The panel says Only an Owner or Admin changes it.
- Under Choose the scanner's port, tap COM1 (with an adapter, the adapter's port; on a Mac the one starting /dev/cu.). The scale's port is marked the scale's port and can't be chosen.
- Press Save. The toast says Scanner saved. and the Scanner row says Connected on COM1.
The scale (COM2):
- Press Change on the Scale row. The panel says The scale works out the price.
- Choose COM2 in Choose the scale's port. The scanner's port is marked the scanner's port and can't be chosen.
- Press Turn on (Save if the scale was already on). The toast says Scale saved. and the Scale row says Connected on COM2 and The scale works out the price.
- When the scale first starts, it asks the till for a check. Once it accepts it, Change shows Scale check: The scale accepted this till.
The till never uses one port for both: choosing the other device's port says, for example, COM2 is the scale's port. Choose the port the scanner's cable is in.
Where to find the Hardware screen on the till
On the till, tap Settings, then Hardware. Each device has a row with its status, the model and its badge, a Setup guide button and a large test button.
- Owners, Admins, Shop managers and Supervisors open Hardware and run the tests.
- Owners, Admins and Shop managers also see Change on a row, to set how the device is connected to this till. Only Owners and Admins change the scale.
- Cashiers see Hardware greyed out with "Not allowed for your role". A supervisor or manager signs in to run a test.
Setup guide opens this page: Open in the browser shows it on the till's computer (not in kiosk mode), and Print the link prints the address with a QR code to scan with a phone.
Every test asks you whether it worked (Yes or No). The answer is saved with the till, and your manager sees it in the back office under Settings › Tills and devices, in the till's Hardware tests.

5. Test it
Wait 15 minutes after switching the Magellan on before you test the weight.
- Barcodes: on the Scanner row, press Test scan and scan a product, then the test QR code in the printed guide (the till shows ITSPOS QR TEST 123), then an itsPass code on a phone (brightness full, 10 to 15 cm from the upright window, tilted slightly), then a fresh food barcode if you have one. The till shows "The scanner works." and the barcode.
- Weight: on the Scale row, press Read weight. The till sends the scale a test price of £1.00 per kg. Put something you know the weight of on the scale, for example a 1 kg bag of sugar, and press Weigh. The till shows the scale's answer, for example 1.000 kg · £1.00. If the weight is right and the price matches it, press Yes; otherwise No.
The results are saved with the till, and your manager sees them in the back office under Settings › Tills and devices. There is no Zero button for this scale: zero it with the scale's own zero key.
Trade use
Until trade use is switched on for this till, the Scale row says Not for trade use until an Owner or Admin switches on trade use in the back office, and weighed items can't be sold from the scale. Once an approved verifier or Trading Standards has checked the scale and the till together in your shop, an Owner or Admin switches it on in Settings › Compliance › Weighed goods, ticking a declaration that the set-up is verified: Selling by weight legally › Switch on trade use.
Changing the scale's port, its cable or the profile's scale switches trade use off again and shows Scale needs re-checking. Changing the scanner's port doesn't: the scanner doesn't weigh.
The verifier reads the till's weighing software on the till: Settings › Hardware, Scale row, "Weighing software 1.0.0 · checksum 3afbc0df" (till 0.5.43 and later; Change shows the full checksum). An update that changes it switches trade use off with Scale needs re-checking, like a change of the scale.
What this changes
- Sell: barcodes from the Magellan arrive on COM1 like any scan; the scan box stays ready. Tapping or scanning a product sold by weight opens the weigh sheet with The scale works out the price; the till sends the product's price per kg (and its tare) to the scale.
- Receipts: the receipt and the customer display show the weight, the price per kg and the price exactly as the scale worked them out; staff can't change them on the till. A weighed sale needs a working receipt printer, so keep paper in it.
- Back office: Settings › Tills and devices shows the till's scanner on its serial port and its scale; Settings › Compliance › Weighed goods lists each till's scale and its trade use.
Common problems
| What happens | What to do |
|---|---|
| The Scanner row says Choose the scanner's port | An Owner or Admin presses Change on the Scanner row, taps COM1, then Save. |
| Scanner disconnected, or Can't open the scanner's port with a reason in brackets | Check the HOST cable at both ends. Another program may be using COM1: close any earlier till program. The till tries again by itself every few seconds. |
| COM2 is the scale's port. Choose the port the scanner's cable is in. (or the other way round) | Each cable has its own port. Check which cable goes where (HOST to COM1, SCALE HOST to COM2) and choose the other port. |
| A setting barcode gives no beeps | Cover the other barcodes and move the page slowly nearer and further from the upright window. If the Magellan's lights are off, wave a hand in front of it. Check you printed at 100% size. |
| Six very quick chirps and no restart | The Magellan refused the barcode: cover the others and scan it again. Still the same: take everything off the platter, pull its power plug for 30 seconds and scan it again. Barcodes 14 and 15 are for newer Magellans: if one of them chirps, carry on. |
| The green light flashes slowly, one second on and one second off | The Magellan is waiting for setting barcodes, usually after an Enter/Exit barcode from an older guide. Pull its power plug for 30 seconds, plug it back in and scan the barcode again. |
| The Magellan beeps but no barcode reaches the till | Check the cable is in the Magellan's blue HOST PORT (not the auxiliary port) and in COM1. Still nothing: unplug both cables from the till and start again from barcode 1 of the printed guide. |
| Product barcodes scan, but QR codes, itsPass codes or fresh food barcodes don't | Scan barcodes 7 to 12 again: QR, Data Matrix and GS1 DataBar are off from the factory. Still the same: unplug both cables from the till and start again from barcode 1. |
| No square code reads at all, not even the test QR code on paper | If products still scan after barcodes 7 to 12, the Magellan's 2D camera may need a repair: QR codes, itsPass codes, Data Matrix and reading from phone screens all depend on it. Call us. |
| The test QR code scans from paper, but not from a phone | Scan barcodes 13 to 15 again. Turn the phone's brightness up, hold it 10 to 15 cm from the upright window and tilt it slightly; switch off dark mode so the code is dark on white. |
| Barcodes arrive with a letter in front, for example F5012345678900 | Scan barcodes 3 and 4 again: they turn that letter off and add the code the till reads instead. |
| Scale not responding, The scale isn't answering or The scale didn't accept the till's message | Check the SCALE HOST cable is in COM2 at both ends and the Magellan is on, then scan barcodes 17 to 19 again. If it keeps happening, call us; don't change the scale's other settings. |
| Any message on the Scale row | The Magellan 9800i with Dialog06 guide's "Common problems" says what each one means: the scale side is the same. |
| A yellow Scale needs re-checking note | Someone changed the scale settings or its connection. Weighed items show "Not for trade use" until an Owner or Admin switches trade use on again in Settings › Compliance › Weighed goods. |
For installers
- HOST port: Interface Type RS-232 Standard (
000105). Its factory settings are 9600 baud, 8 data bits, no parity, 1 stop bit, RS-232 Hardware Control off and Global Suffix CR (PRG Appendix F); barcodes 20 to 25 of the printed guide set them explicitly:001D01,009B01,002200,001F00,020F00,031E0D00. - The printed two-cable guide uses single-label programming barcodes, each saved on its own (no Enter/Exit), in this order: factory defaults (
7FFC00), RS-232 Standard (000105), session 2 (below), cell phone mode always on (046702), frame rate 20% (047101), cell phone reading at the horizontal and vertical windows (046D03), TDR off (046000), the SCALE HOST settings (below), then the HOST port settings above. Its extra pages hold the security tag, handheld and top-down reader codes listed in the one-cable guide. - The till opens the HOST port's COM port at 9600 8-N-1, raises RTS and DTR (harmless with Hardware Control off; it lets the scanner send if CTS flow or scan control is on) and never writes to it. Each line ending in CR or LF is one barcode, with its AIM ID; a line with no ending is taken after 120 ms of quiet. Without AIM IDs, the factory Label IDs in front of EAN and UPC barcodes (
A,E,F,FF) are taken off. - Not RS-232 Single Cable (
000120): "Single cable installations require connection at the POS Terminal (host) port. The Scale Host port connection is not used for this interface" (PRG, Interface Type). - Session 2: Global AIM ID on (
03A901), Label ID off (020500), zero return "no zero between weights" (040802), ScaleSentry override off (046300), QR (03D701), GS1 QR (047501), Data Matrix (010001), GS1 Data Matrix (047401), GS1 DataBar Omnidirectional (04D001) and Expanded (04D101). - SCALE HOST port: Scale Interface Type Dialog06 (
040411), Scale Baud Rate 9600 (041304), Scale Interface Options "clear the unit price after every price-weight request" (041708). Checkout-Dialog 06 at 9600 baud, 7 data bits, odd parity, 1 stop bit, no handshake lines. - Till profile:
scanner.typeserial,scale.modelmagellan_9800i_dialog06; both ports are chosen on the till, and the till refuses one port for both. - Still to be confirmed by Datalogic: that its UK approval covers Dialog06 with a PC till; how the 9800i answers the scale check (records 10 and 11) for a PC till; and that RS-232 Standard on the HOST port together with Dialog06 on the SCALE HOST port is a combination it supports (the PRG documents each on its own).
Still stuck?
The itsPOS support team is here 08:00 to 20:00 every day except Christmas Day.
- Call or WhatsApp: +44 7488 880320
- Email: support@itspos.io
- In the back office: Help › Contact support, or go to app.itspos.io/help/contact after you sign in
- On our website: itspos.io/contact
Tell us your shop's name and what you were trying to do. A screenshot of the screen helps.